Analytical Sciences
Online ISSN : 1348-2246
Print ISSN : 0910-6340
ISSN-L : 0910-6340
Original Papers
Colloidal Titration of Aqueous Zirconium Solutions with Poly(vinyl sulfate) by Potentiometric Endpoint Detection Using a Toluidine Blue Selective Electrode
Osamu SAKURADAYasutake KATONoriyoshi KITOKeiichi KAMEYAMAToshiaki HATTORIMinoru HASHIBA
Author information
JOURNAL FREE ACCESS

2004 Volume 20 Issue 2 Pages 311-314

Details
Abstract

Zirconium oxy-salts were hydrolyzed to form positively charged polymer or cluster species in acidic solutions. The zirconium hydrolyzed polymer was found to react with a negatively charged polyelectrolyte, such as poly(vinyl sulfate), and to form a stoichiometric polyion complex. Thus, colloidal titration with poly(vinyl sulfate) was applied to measure the zirconium concentration in an acidic solution by using a Toluidine Blue selective plasticized poly(vinyl chloride) membrane electrode as a potentiometric end-point detecting device. The determination could be performed with 1% of the relative standard deviation. The colloidal titration stoichiometry at pH ≤ 2 was one mol of zirconium per equivalent mol of poly(vinyl sulfate).

Content from these authors
© 2004 by The Japan Society for Analytical Chemistry
Previous article Next article
feedback
Top